High Temperature, Low Strain, Extended Performance Capacitive Extensometers (1200°C or 1600°C) – Model 7650A
Operation of these, and all of Epsilon’s extensometers, are
VERIFIED TO APPLICABLE STANDARDS SUCH AS ASTM E83 OR ISO 9513
using in-house calibration systems that are calibrated with Epsilon’s laser interferometer system.
WITH EPSILON’S 20+ YEAR HISTORY OF SERVICE
to the materials testing community, you know we will be there to stand behind our products when your critical application requires it.
Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.
All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.
These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.
These liquid-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200 °C (2200 °F). Silicon carbide rods are used for the 1600 °C (2900 °F) high temperature option.
The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.
- May be left on through specimen failure.
- Hot mountable and retractable.
- Self-setting gauge length with fine adjustment feature.
- All models can measure in both tension and compression and may be used for cyclic testing at test frequencies up to 10 Hz.
- Ships fully calibrated with calibration that is traceable to NPL; voltage output may be user-specified (typically 0-10V).
- Excellent ambient vibration rejection; primary vibration mode >100 Hz typical
- Digital controller and power supply included. Provides high level DC voltage output with low noise. Easily interfaced to test controllers, data acquisition boards and chart recorders.
- Includes high speed analog and digital outputs.
- Web-based user interface for setup and data acquisition.
- Selectable analog and digital filter options from 2 Hz to 3 kHz.
- Built-in calibration reference and auto-zero features.
- Multiple extensometer calibration files may be loaded for use with one controller.
- Can be used with specimens at elevated temperatures while only requiring room temperature calibration.
- Quick-disconnect liquid cooling fittings and signal cables.
- Includes high quality foam lined case and a spare set of rods.
Analog Output: User specified, ±10VDC typical, ±10.8VDC rail
Digital Output: 24 bit high speed Ethernet output with built-in web interface
Cyclic Testing: up to 10 Hz, depending on test system and test amplitude
Accuracy: Standard configurations meet ASTM E83 class B-1 and ISO 9513 class 0,5 requirements for accuracy. A test certificate is included. Rod lengths >250 mm (10″) can affect the final class rating.
Linearity: 11 point digital linearization, ≤0.1% FS typical linearity
Hysteresis: ≤0.1% FS typical
Resolution: <75 PPM (0.0075%FS) RMS @ 4 kHz, <6 PPM (0.0006%FS) @ 100 Hz at gauge length
Filter: Selectable 100 Hz analog and 2 Hz – 3 kHz digital filters
Sensor Cable: 2 m (6.5 ft) room temperature cable
Output Cable: Flexible 2.4 m (8 ft) analog output cable
Coolant Interface: Two barbed hose fittings for 1/8” (3.2 mm) ID coolant hoses
Operating Force: <30 grams typical
Contact Force: <560 grams typical
Environment: Recommended for testing in dry air, inert / non-corrosive gases
Power: Includes power supply for your country
- Model EPS170 constant-temperature recirculating chiller (size: 190 mm L x 130 mm W x 180 mm H; weight: 3.5kg; power: 100-240VAC, 200W)
Liquid cooling is recommended for all elevated temperature tests to obtain the best measurement accuracy and retain the validity of a room temperature calibration when the specimen temperature is >540 °C (1000 °F). Cooling is necessary to prevent extensometer damage for testing in the range of ~800-1600 °C (1500-2900 °F). Epsilon Technology recommends the EPS170 constant-temperature recirculating chiller. - High temperature option (-HT suffix) for use to 1600°C
- Rod tips can be straight chisels or conical tips; specify when ordering
- Load frame mounting brackets
- Connectors to interface to nearly any brand of test equipment
Ordering Information
Click table options to configure
mm or inches | # |
---|---|
12.5 mm | -0125M |
25.0 mm | -025M |
0.500 in | -0050 |
1.000 in | -0100 |
extension | # |
---|---|
+1.5 / -1.5 mm | –015M |
+2.0 / -1.0 mm | –020M |
+2.5 / -0.5 mm | –025M |
+0.060 / -0.060 in | –060T |
+0.080 / -0.040 in | –080T |
+0.100 / -0.020 in | –100T |
degrees | # |
---|---|
Room temperature to 1200 °C (2200 °F) | -ST |
Room temperature to 1600 °C (2900 °F) | -HT |
Selected Tensile Measuring Range: _ _ _ _
Requires external mounting brackets and 110 – 240VAC / 4W electrical power. Water cooling is recommended; required for 1000 °C and above.
Other configurations are available with special order; please contact Epsilon to discuss your requirements.
Related Models
Repairs/Service
If your unit is in need of service, calibration or repair, initiate the RMA process with us and we will be happy to assist.
Get Our Newsletter
Sign up for our newsletter to get the most up-to-date information on products and services.
Download Catalog
Our 2022 Extensometer Catalog, Version 110 is now available! Not finding something you’re looking for? Ask us about a custom quote.